System Selection
For optimal outdoor cooling in the Gulf region, we recommend the Advanced Evaporative Cooling System. This system boasts an evaporation rate exceeding 95% and is controlled via humidity or temperature sensors for maximum efficiency.
Key Components
- Water Mist System: Provides efficient cooling through fine mist distribution.
- Steam Cooling Humidifiers: Enhance the cooling effect by adding moisture to the air
- In Riyadh, the system can reduce the supply air temperature from 50°C to 24°C.
- In Jeddah and Dammam, the system effectively lowers the supply air temperature from 50°C to 28°C.
Advanced Water Mist System and Cold Steam Cooling Humidifiers for Outdoor Cooling
Applications Our Advanced Water Mist System and Cold Steam Cooling Humidifiers are widely used for outdoor cooling applications. These systems are known for their efficiency and reliability in extreme conditions.
Performance in Mega Projects Over the past fifteen years, Hybrlab’s Advanced Water Mist System and outdoor cooling solutions have been the top choice for major projects across the Gulf region. Their superior performance and durability make them ideal for large-scale applications.
Commitment to Sustainability Hybrlab’s Advanced Water Mist System and outdoor cooling solutions are designed to meet international sustainability standards. Our systems not only provide effective cooling but also contribute to environmentally responsible practices.
Electrical Power Supply for Different Outdoor Cooling Systems at 45°C Ambient
Air-Cooled Chillers
- System Components: Includes chillers, AHUs, pumps, etc.
- Power Consumption: Approximately 1.6 kW per ton of refrigerant.
- System Overview: Comprehensive outdoor cooling solution.
- Power Consumption: Approximately 1.5 kW per ton of refrigerant
- Perfomance: Evaporation rate exceeds 95%.
- Power Consumption: Approximately 0.1 kW per ton of refrigerant.
- Perfomance: 100% evaporation rate.
- Power Consumption: Approximately 0.05 kW per ton of refrigerant.
- Perfomance: Evaporation rate approximately 5%.
- Power Consumption: Approximately 0.6 kW per ton of refrigerant.
- Perfomance: Evaporation rate approximately 5%.
- Power Consumption: Approximately 0.5 kW per ton of refrigerant.
Initial Cost and Lifetime for Outdoor Cooling Systems
Initial CostAir-Cooled Chillers
- System Components: Chillers, AHUs, pumps, etc.
- Cost: Approximately $1600 per ton of refrigerant (materials only, installation not included).
- System Overview: Comprehensive outdoor cooling solution
- Cost: Approximately $600 per ton of refrigerant (materials only, installation not included).
- Perfomance Evaporation rate exceeds 95%.
- Cost: : Approximately $150 per ton of refrigerant (materials only, installation not included).
- Perfomance: 100% evaporation rate.
- Cost: Approximately $175 per ton of refrigerant (materials only, installation not included).
- performance: Evaporation rate approximately 5%.
- Cost: Approximately $100 per ton of refrigerant (materials only, installation not included).
- Perfomance: Evaporation rate approximately 5%.
- Cost: Approximately $200 per ton of refrigerant (materials only, installation not included).
Lifetime
- Air-Cooled Chillers: Approximately 15 to 20 years.
- Air-Cooled DX Package Units: Approximately 15 years.
- Advanced High-Pressure Mist System: Approximately 15 years.
- Cold Steam Cooling Humidifiers: Approximately 15 to 20 years.
- Standard Evaporative Cooling System: Approximately 5 to 8 years.
- Direct and Indirect Evaporative Cooling System: Approximately 5 to 8 years.